01
It's usually the wire, not the light
Most low-voltage lighting failures are a bad connection or a wire nicked by an edger or a shovel. Swapping fixtures rarely fixes a dead run.
What we do · Hardscape, lighting & irrigation
Dead fixtures, dark runs and broken timers tracked down and fixed on an existing low-voltage system.
From $340 · Half Day, one-person crew
Why call us
We find the actual fault instead of replacing fixtures until something works. Flat Half Day or Full Day price, with any parts quoted as their own line.
Where the price starts
From $340
Half Day, one-person crew

What we know
Useful whether or not you ever call us.
01
Most low-voltage lighting failures are a bad connection or a wire nicked by an edger or a shovel. Swapping fixtures rarely fixes a dead run.
02
If nothing comes on, look at the GFCI outlet the transformer plugs into, then the timer. Power flickers reset timers, and a tripped GFCI looks exactly like a dead system.
03
Lights getting dimmer the farther they are from the transformer usually means too many fixtures on one run or cable too thin for the distance.
04
The clip-on piercing connectors that come with a lot of kits let water in and corrode. Gel-filled waterproof connectors last far longer in wet ground.
05
A shrub growing over the photocell makes the system think it's dark all day or light all night. Trim around it.
Questions
Usually a failed splice or a cut wire on that run. Everything past the break goes dark while everything before it keeps working.
Often, yes, by swapping the bulbs on the existing fixtures. LEDs also take load off the transformer, which can fix dim lights at the end of a run.
No. We repair and replace parts of systems that are already in the ground. A new system designed from scratch isn't something we take on.
What we don’t do
Where we do it
Related work
Next step
A picture tells us more than a form does. Text one over and we'll come back with a price — the message already says what it's about.
Or call